Previous
Adult Oxygen Face Mask Price in Bangladesh

Adult Oxygen Face Mask Price in Bangladesh

Original price was: 399.00৳ .Current price is: 350.00৳ .
Next

40 Liter Oxygen Cylinder Price in Bangladesh

Original price was: 28,000.00৳ .Current price is: 26,000.00৳ .
40 Liter Oxygen Cylinder Price in Bangladesh

Oxygen Cylinder Humidifier Bottle Price in Bangladesh

Original price was: 1,000.00৳ .Current price is: 800.00৳ .

Medical-grade oxygen from a cylinder is extremely dry — drier than any air a patient would normally breathe. Delivering it directly into the airways without humidification during extended therapy sessions causes dryness, nosebleeds, throat irritation, and discomfort. An Oxygen Cylinder Humidifier Bottle solves this by adding controlled moisture to the oxygen flow before it reaches the patient. At Choice Bangla, oxygen cylinder humidifier bottles are available from ৳800, with free home delivery in Dhaka. Call 01308804911.

What it does:

● Adds moisture to dry compressed oxygen before it reaches the patient

● Prevents nasal dryness, nosebleeds, and throat irritation during extended use

● Works at flow rates of 2 LPM and above — most beneficial above 4 LPM

● Attaches directly to the flow meter regulator outlet — no tools needed

● 250–500ml capacity — enough for 8–12 hours of continuous therapy

Key specs:

● Material: Medical-grade PC (polycarbonate) or high-temp PVC

● Capacity: 250–500ml

● Pressure rated: matches standard flow meter output

● Sterile-grade internal surface

● Easy-open cap for water refilling

● Universal fit — compatible with most standard flow meters in Bangladesh

When you actually need it: At flow rates below 2 LPM for short sessions — humidification is optional. At 2 LPM and above for sessions longer than 30 minutes — a humidifier bottle is strongly recommended.

Service: Free home delivery in Dhaka within 2 hours. Available 24/7. Call 01308804911.

SPECIFICATION

Specification Details
Product Oxygen Cylinder Humidifier Bottle
Material Medical-grade PC (polycarbonate) or high-temp PVC
Capacity 250–500ml
Color White/Gray or transparent
Pressure Rating Compatible with standard flow meter output
Internal Surface Sterile-grade
Inlet/Outlet Standard barb fitting — universal flow meter compatible
Cap Easy-open for water refilling
Water Type Required Sterile or distilled water only
Fill Level One-third of bottle capacity
Replacement Interval Every 4–6 weeks (daily use)
Compatibility Standard cylinder flow meters — China, Islam, Linde, Rama
Best For Oxygen therapy sessions 30+ minutes at 2 LPM and above
Not For Oxygen concentrator (different product — different fitting)
Category:

Description

There is a piece of oxygen therapy equipment that most people overlook until a patient starts complaining of a dry nose, nosebleeds, or a sore throat after a few days of oxygen use. That piece of equipment is the oxygen cylinder humidifier bottle — a small but genuinely important accessory that makes a significant difference to patient comfort during extended oxygen therapy.

At Choice Bangla, Oxygen Cylinder Humidifier Bottle price in Bangladesh starts from ৳800, with free home delivery in Dhaka. Call 01308804911 anytime.

Why compressed oxygen causes airway dryness — and why this matters

This is the explanation that no competitor in Bangladesh has bothered to provide, but it is the most important piece of context for this product.

The oxygen stored in a medical cylinder is highly compressed and extremely dry — it has essentially zero humidity. Normal room air in Bangladesh contains significant moisture, especially in the humid months. When a patient breathes compressed oxygen directly from a cylinder without humidification, they are breathing air that is far drier than anything their airways would normally experience.

Over time — and for many patients, within just a few hours — this causes the mucous membranes in the nose and throat to dry out. The result is nasal discomfort, nosebleeds (particularly common in elderly patients), throat irritation, and in some cases, increased susceptibility to respiratory infection because the dry mucous membranes lose some of their natural protective function.

A humidifier bottle adds controlled moisture back into the oxygen flow before it reaches the patient. The oxygen bubbles through a small reservoir of sterile water, picking up moisture, and arrives at the patient’s nose or mouth in a condition much closer to normal breathable air. The difference in patient comfort — particularly for patients on ongoing daily therapy — is substantial.

One important clarification — cylinder humidifier vs concentrator humidifier

This is where almost every competitor listing in Bangladesh creates confusion, and it is worth being direct about.

The humidifier bottle used with an oxygen cylinder flow meter is a different product from the humidifier bottle used with an oxygen concentrator. The fittings are different, the pressure ratings are different, and in many cases the price is different.

Cylinder flow meter humidifier bottles — the product on this page — are compact, typically 250ml, and attach to the outlet port of a standard flow meter regulator. They cost ৳600–800 in Bangladesh.

Oxygen concentrator humidifier bottles are larger, rated for the concentrator’s specific outlet pressure, and cost ৳2,500–2,950 in Bangladesh. These are not interchangeable with cylinder flow meters.

If you have a cylinder and need a humidifier, the ৳300–600 option is what you need. If you have a concentrator, call Choice Bangla on 01308804911 to confirm the right product for your specific concentrator model.

When do you actually need a humidifier bottle

Humidification is not equally necessary for all oxygen therapy situations. Here is honest guidance on when it matters and when it does not.

Humidification is strongly recommended when:

● Flow rate is 2 LPM or above

● Therapy sessions last longer than 30 minutes

● The patient is elderly — airways dry out faster

● The patient already has nasal dryness or nosebleeds

● Oxygen therapy is continuous or near-continuous throughout the day

Humidification is optional (but not harmful) when:

● Flow rate is 1–2 LPM for short sessions under 30 minutes

● The patient has no nasal discomfort and therapy is brief and occasional

The British Thoracic Society — the primary clinical authority on oxygen therapy — recommends humidification for flow rates above 4 LPM for extended sessions. Many Bangladeshi home care setups at 1–2 LPM can manage without humidification short-term, but most patients on daily therapy benefit from it.

How to use an oxygen cylinder humidifier bottle correctly

Filling: Fill the bottle to exactly one-third of its total capacity — not more. Overfilling causes water to be pushed into the oxygen tubing and potentially reach the patient’s mask or cannula, which is uncomfortable and unhygienic. The one-third level creates the right air gap above the water for the oxygen to bubble through effectively.

Always use sterile water or distilled water — never tap water. Tap water in Bangladesh contains chlorine, minerals, and in some areas microorganisms that should not be introduced directly into a patient’s airways. Sterile water is available at pharmacies throughout Dhaka. Distilled water (used in batteries) is a practical and cost-effective alternative.

Attachment: Unscrew the bottom cap of the humidifier bottle. Fill to one-third. Replace the cap. Connect the bottle inlet to the flow meter outlet port — it screws on and should seal firmly without excessive force. Connect your nasal cannula or mask tubing to the humidifier bottle outlet. Open the cylinder valve, set the flow rate, and confirm oxygen is flowing by checking for bubbling inside the bottle. Visible bubbling confirms the oxygen is passing through the water correctly.

Daily maintenance: Empty and rinse the bottle every 24–48 hours during active use. Do not allow water to sit in the bottle for more than 48 hours — stagnant water in a warm environment creates a bacterial growth risk. Refill with fresh sterile water.

Cleaning: Once a week, wash the bottle and all fittings with mild soap and warm water. Rinse thoroughly — soap residue must be completely removed. Dry completely before refilling. Do not use alcohol or bleach on the bottle interior; these chemicals degrade the plastic and are harmful if inhaled.

Replacement: Replace the humidifier bottle every 4–6 weeks for patients using oxygen daily. Even with proper cleaning, the internal surface of the bottle degrades over time and the seal quality at the cap and fittings reduces. A cracked or poorly sealing bottle allows unhumidified oxygen to bypass the water — defeating the purpose entirely. At ৳300–600, replacement is not a significant cost.

Signs the humidifier bottle needs replacing

Watch for these: visible cracks or cloudiness in the bottle body; the cap does not seal snugly and leaks; the oxygen no longer bubbles visibly through the water at normal flow rates (indicates a bypass leak); or a persistent musty smell from the bottle even after cleaning.

Why Choice Bangla

We stock both standard cylinder humidifier bottles (৳600–800) and concentrator-grade humidifier bottles (৳2,500+). Every order is confirmed for compatibility with your specific flow meter before delivery. Free delivery in Dhaka within 2 hours.

● Oxygen cylinder humidifier bottles from ৳800

● Compatible with all standard cylinder flow meters — China, Islam, Linde, Rama

● Free home delivery in Dhaka (2 hours)

● Available 24/7 including nights

● Cash on delivery

● Compatibility confirmation before ordering — call 01308804911

Frequently asked questions

What is the oxygen cylinder humidifier bottle price in Bangladesh? From ৳800 for a standard cylinder flow meter humidifier bottle. Concentrator-grade humidifier bottles cost ৳2,500–2,950. At Choice Bangla, free delivery in Dhaka. Call 01308804911.

What is the difference between a cylinder humidifier bottle and a concentrator humidifier bottle? They are different products with different fittings and pressure ratings. Cylinder bottles cost ৳600–800 and attach to the flow meter outlet. Concentrator bottles cost ৳2,500–2,950 and are specific to the concentrator model. They are not interchangeable.

What water should I use in the humidifier bottle? Sterile water or distilled water only. Never tap water. Fill to one-third of the bottle capacity.

How often should I change the water? Every 24–48 hours during active use. Never leave water in the bottle for more than 48 hours.

How often should I replace the humidifier bottle? Every 4–6 weeks for daily users. Replace immediately if cracks appear or the bottle no longer bubbles properly.

Do I always need a humidifier bottle with an oxygen cylinder? Not always. At 1–2 LPM for short sessions, it is optional. At 2 LPM and above for sessions over 30 minutes, it is strongly recommended. For elderly patients or anyone with nasal discomfort, use it regardless of flow rate.

How do I know oxygen is flowing through the bottle correctly? You will see visible bubbling inside the bottle when the cylinder valve is open and the flow rate is set. No bubbling means the oxygen is bypassing the water — check the connections.

How fast is delivery in Dhaka? Within 2 hours. Available 24/7. Call 01308804911.

Call Choice Bangla: 01308804911 choicebangla.com | Humidifier bottles from ৳800 | Free delivery Dhaka | 24/7 | Cash on delivery

Reviews

There are no reviews yet.

Be the first to review “Oxygen Cylinder Humidifier Bottle Price in Bangladesh”

Your email address will not be published. Required fields are marked *

Shopping cart

1

Subtotal: 4,500.00৳ 

View cartCheckout